Anomaly Detection
< Home | = Overview | = Services | = Streaming Services | __ Stream Analytics__ | = Anomaly Detection
Built-in machine learning capabilities for detecting anomalies in streaming data.
< Overview¶
Azure Stream Analytics includes built-in machine learning models for anomaly detection without requiring data science expertise. These functions detect unusual patterns in streaming data in real-time.
Supported Anomaly Types¶
- Spikes: Sudden increase in values
- Dips: Sudden decrease in values
- Slow Positive Trends: Gradual upward drift
- Slow Negative Trends: Gradual downward drift
- Bidirectional Level Changes: Step changes up or down
graph TB
subgraph "Normal Pattern"
Normal[Steady<br/>Baseline]
end
subgraph "Anomalies"
Spike[Spike<br/>]
Dip[Dip<br/>]
TrendUp[Slow Positive<br/>Trend ]
TrendDown[Slow Negative<br/>Trend ]
LevelChange[Level<br/>Change]
end
Normal --> Spike
Normal --> Dip
Normal --> TrendUp
Normal --> TrendDown
Normal --> LevelChange =' Anomaly Detection Functions¶
AnomalyDetection_SpikeAndDip¶
Detects spikes and dips in time-series data.
-- Basic spike and dip detection
SELECT
deviceId,
temperature,
AnomalyDetection_SpikeAndDip(temperature, 95, 120, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 1)) AS anomalyScore
INTO
[anomaly-output]
FROM
[sensor-input]
Parameters: - Column: The numeric column to analyze (e.g., temperature) - Confidence: Confidence level (0-100), typically 95 - History Size: Number of events to consider (e.g., 120) - Mode: 'spikes', 'dips', or 'spikesanddips'
Output Fields: - Score: Anomaly score (0-1, higher = more anomalous) - IsAnomaly: Boolean flag (1 = anomaly detected)
AnomalyDetection_ChangePoint¶
Detects persistent changes in the level or trend of time-series data.
-- Detect level changes in metrics
SELECT
metricName,
value,
AnomalyDetection_ChangePoint(value, 95, 120)
OVER(PARTITION BY metricName LIMIT DURATION(hour, 1)) AS changePoint
INTO
[changepoint-output]
FROM
[metrics-input]
Use Cases: - Detecting system configuration changes - Identifying service degradation - Monitoring baseline shifts
= Practical Examples¶
Example 1: Temperature Anomaly Detection¶
-- Comprehensive temperature monitoring with anomaly detection
WITH TemperatureData AS (
SELECT
deviceId,
location,
temperature,
System.Timestamp() AS eventTime
FROM
[sensor-input]
),
AnomalyDetection AS (
SELECT
deviceId,
location,
temperature,
eventTime,
AnomalyDetection_SpikeAndDip(temperature, 95, 120, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 2)) AS spikeAndDip,
AnomalyDetection_ChangePoint(temperature, 95, 120)
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 2)) AS changePoint
FROM
TemperatureData
)
-- Output anomalies with context
SELECT
deviceId,
location,
temperature,
eventTime,
spikeAndDip.Score AS spikeScore,
spikeAndDip.IsAnomaly AS isSpikeAnomaly,
changePoint.Score AS changePointScore,
changePoint.IsAnomaly AS isChangePoint,
CASE
WHEN spikeAndDip.IsAnomaly = 1 AND spikeAndDip.Score > 0.8 THEN 'Critical Spike/Dip'
WHEN changePoint.IsAnomaly = 1 THEN 'Level Change Detected'
ELSE 'Normal'
END AS anomalyType
INTO
[temperature-anomalies]
FROM
AnomalyDetection
WHERE
spikeAndDip.IsAnomaly = 1 OR changePoint.IsAnomaly = 1
// C# consumer to process anomalies
using Azure.Messaging.EventHubs.Consumer;
using System;
using System.Text.Json;
public class AnomalyProcessor
{
public async Task ProcessAnomaliesAsync(string connectionString, string eventHubName)
{
await using var consumer = new EventHubConsumerClient(
EventHubConsumerClient.DefaultConsumerGroupName,
connectionString,
eventHubName);
await foreach (PartitionEvent partitionEvent in consumer.ReadEventsAsync())
{
var anomaly = JsonSerializer.Deserialize<TemperatureAnomaly>(
partitionEvent.Data.EventBody.ToString());
Console.WriteLine($"Anomaly detected for device {anomaly.DeviceId}");
Console.WriteLine($" Type: {anomaly.AnomalyType}");
Console.WriteLine($" Temperature: {anomaly.Temperature}C");
Console.WriteLine($" Spike Score: {anomaly.SpikeScore:F2}");
if (anomaly.AnomalyType == "Critical Spike/Dip")
{
await SendAlertAsync(anomaly);
}
}
}
private async Task SendAlertAsync(TemperatureAnomaly anomaly)
{
// Send alert via email, SMS, or notification service
Console.WriteLine($"= ALERT: Critical anomaly for device {anomaly.DeviceId}");
}
}
public record TemperatureAnomaly(
string DeviceId,
string Location,
double Temperature,
DateTime EventTime,
double SpikeScore,
bool IsSpikeAnomaly,
double ChangePointScore,
bool IsChangePoint,
string AnomalyType
);
Example 2: Network Traffic Anomaly Detection¶
-- Detect unusual network traffic patterns
WITH NetworkMetrics AS (
SELECT
serverId,
bytesReceived,
bytesSent,
connectionCount,
System.Timestamp() AS timestamp
FROM
[network-input]
GROUP BY
serverId,
bytesReceived,
bytesSent,
connectionCount,
TumblingWindow(second, 30)
),
TrafficAnomalies AS (
SELECT
serverId,
bytesReceived,
bytesSent,
connectionCount,
timestamp,
AnomalyDetection_SpikeAndDip(bytesReceived, 95, 240, 'spikes')
OVER(PARTITION BY serverId LIMIT DURATION(minute, 30)) AS receivedAnomaly,
AnomalyDetection_SpikeAndDip(bytesSent, 95, 240, 'spikes')
OVER(PARTITION BY serverId LIMIT DURATION(minute, 30)) AS sentAnomaly,
AnomalyDetection_SpikeAndDip(connectionCount, 95, 240, 'spikes')
OVER(PARTITION BY serverId LIMIT DURATION(minute, 30)) AS connAnomaly
FROM
NetworkMetrics
)
-- Flag potential DDoS or security incidents
SELECT
serverId,
bytesReceived / 1024 / 1024 AS mbReceived,
bytesSent / 1024 / 1024 AS mbSent,
connectionCount,
timestamp,
receivedAnomaly.Score AS receivedAnomalyScore,
sentAnomaly.Score AS sentAnomalyScore,
connAnomaly.Score AS connAnomalyScore,
CASE
WHEN receivedAnomaly.IsAnomaly = 1 AND connAnomaly.IsAnomaly = 1
THEN 'Potential DDoS Attack'
WHEN sentAnomaly.IsAnomaly = 1 AND sentAnomaly.Score > 0.9
THEN 'Potential Data Exfiltration'
WHEN receivedAnomaly.IsAnomaly = 1
THEN 'Unusual Inbound Traffic'
ELSE 'Traffic Anomaly'
END AS securityAlert
INTO
[security-alerts]
FROM
TrafficAnomalies
WHERE
receivedAnomaly.IsAnomaly = 1
OR sentAnomaly.IsAnomaly = 1
OR connAnomaly.IsAnomaly = 1
Example 3: Application Performance Monitoring¶
-- Monitor application response times for anomalies
WITH ResponseTimeMetrics AS (
SELECT
applicationName,
endpoint,
AVG(responseTime) AS avgResponseTime,
MAX(responseTime) AS maxResponseTime,
COUNT(*) AS requestCount,
System.Timestamp() AS windowEnd
FROM
[app-logs]
GROUP BY
applicationName,
endpoint,
TumblingWindow(minute, 1)
),
PerformanceAnomalies AS (
SELECT
applicationName,
endpoint,
avgResponseTime,
maxResponseTime,
requestCount,
windowEnd,
AnomalyDetection_SpikeAndDip(avgResponseTime, 95, 120, 'spikes')
OVER(PARTITION BY applicationName, endpoint LIMIT DURATION(hour, 1)) AS responseAnomaly,
AnomalyDetection_ChangePoint(avgResponseTime, 95, 120)
OVER(PARTITION BY applicationName, endpoint LIMIT DURATION(hour, 1)) AS performanceChange
FROM
ResponseTimeMetrics
)
-- Alert on performance degradation
SELECT
applicationName,
endpoint,
avgResponseTime,
maxResponseTime,
requestCount,
windowEnd,
responseAnomaly.Score AS anomalyScore,
performanceChange.Score AS changeScore,
CASE
WHEN performanceChange.IsAnomaly = 1 THEN 'Performance Degradation Detected'
WHEN responseAnomaly.IsAnomaly = 1 AND responseAnomaly.Score > 0.9 THEN 'Critical Response Time Spike'
WHEN responseAnomaly.IsAnomaly = 1 THEN 'Response Time Anomaly'
ELSE 'Normal'
END AS alertType
INTO
[performance-alerts]
FROM
PerformanceAnomalies
WHERE
responseAnomaly.IsAnomaly = 1 OR performanceChange.IsAnomaly = 1
< Tuning Anomaly Detection¶
Confidence Level Selection¶
# Python script to evaluate different confidence levels
import numpy as np
from typing import List, Tuple
def evaluate_confidence_levels(
normal_data: List[float],
anomaly_data: List[float]
) -> List[Tuple[int, float, float]]:
"""
Evaluate detection performance at different confidence levels.
Returns: List of (confidence_level, false_positive_rate, true_positive_rate)
"""
confidence_levels = [80, 85, 90, 95, 99]
results = []
for confidence in confidence_levels:
# Simulate anomaly detection threshold
threshold = np.percentile(normal_data, confidence)
# Calculate metrics
false_positives = sum(1 for x in normal_data if x > threshold)
true_positives = sum(1 for x in anomaly_data if x > threshold)
fpr = false_positives / len(normal_data)
tpr = true_positives / len(anomaly_data)
results.append((confidence, fpr, tpr))
print(f"Confidence {confidence}%:")
print(f" False Positive Rate: {fpr:.2%}")
print(f" True Positive Rate: {tpr:.2%}")
print()
return results
# Example usage
normal_temps = [20 + np.random.normal(0, 2) for _ in range(1000)]
anomaly_temps = [20 + np.random.normal(10, 3) for _ in range(100)]
evaluate_confidence_levels(normal_temps, anomaly_temps)
Confidence Level Guidelines: - 95%: Good balance, recommended for most use cases - 99%: More conservative, fewer false positives - 90%: More sensitive, catches more anomalies but more false positives
History Size Selection¶
-- Test different history sizes
-- Small history (60): Fast adaptation, more sensitive to recent changes
SELECT
deviceId,
temperature,
AnomalyDetection_SpikeAndDip(temperature, 95, 60, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(minute, 30)) AS anomaly60
FROM [input]
-- Medium history (120): Balanced approach (recommended)
SELECT
deviceId,
temperature,
AnomalyDetection_SpikeAndDip(temperature, 95, 120, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 1)) AS anomaly120
FROM [input]
-- Large history (240): More stable, less reactive to short-term fluctuations
SELECT
deviceId,
temperature,
AnomalyDetection_SpikeAndDip(temperature, 95, 240, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 2)) AS anomaly240
FROM [input]
= Integration with Alerting¶
Event Grid Integration¶
-- Send anomalies to Event Grid for action
SELECT
deviceId,
temperature,
anomaly.Score AS score,
'TemperatureAnomaly' AS eventType,
System.Timestamp() AS detectionTime
INTO
[eventgrid-output]
FROM
[sensor-input]
CROSS APPLY
AnomalyDetection_SpikeAndDip(temperature, 95, 120, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 1)) AS anomaly
WHERE
anomaly.IsAnomaly = 1
# Python Azure Function triggered by Event Grid
import logging
import json
import azure.functions as func
from azure.communication.email import EmailClient
def main(event: func.EventGridEvent):
"""Process anomaly alert from Stream Analytics."""
result = event.get_json()
logging.info(f"Anomaly detected for device {result['deviceId']}")
logging.info(f" Temperature: {result['temperature']}")
logging.info(f" Anomaly Score: {result['score']}")
# Send email alert
if result['score'] > 0.9:
send_critical_alert(result)
# Update monitoring dashboard
update_dashboard(result)
# Log to monitoring system
log_to_monitoring(result)
def send_critical_alert(anomaly_data):
"""Send critical alert via email."""
email_client = EmailClient.from_connection_string(
os.environ["COMMUNICATION_SERVICES_CONNECTION_STRING"]
)
message = {
"senderAddress": "noreply@contoso.com",
"recipients": {
"to": [{"address": "alerts@contoso.com"}]
},
"content": {
"subject": f"Critical Anomaly: Device {anomaly_data['deviceId']}",
"plainText": f"""
Critical anomaly detected:
Device: {anomaly_data['deviceId']}
Temperature: {anomaly_data['temperature']}C
Anomaly Score: {anomaly_data['score']:.2f}
Time: {anomaly_data['detectionTime']}
"""
}
}
email_client.begin_send(message)
= Advanced Patterns¶
Multi-Metric Anomaly Detection¶
-- Combine multiple metrics for comprehensive anomaly detection
WITH MultiMetricAnomalies AS (
SELECT
deviceId,
temperature,
humidity,
pressure,
AnomalyDetection_SpikeAndDip(temperature, 95, 120, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 1)) AS tempAnomaly,
AnomalyDetection_SpikeAndDip(humidity, 95, 120, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 1)) AS humidityAnomaly,
AnomalyDetection_SpikeAndDip(pressure, 95, 120, 'spikesanddips')
OVER(PARTITION BY deviceId LIMIT DURATION(hour, 1)) AS pressureAnomaly,
System.Timestamp() AS timestamp
FROM
[sensor-input]
)
-- Flag devices with multiple concurrent anomalies
SELECT
deviceId,
temperature,
humidity,
pressure,
timestamp,
(CASE WHEN tempAnomaly.IsAnomaly = 1 THEN 1 ELSE 0 END +
CASE WHEN humidityAnomaly.IsAnomaly = 1 THEN 1 ELSE 0 END +
CASE WHEN pressureAnomaly.IsAnomaly = 1 THEN 1 ELSE 0 END) AS anomalyCount,
CASE
WHEN tempAnomaly.IsAnomaly = 1 AND humidityAnomaly.IsAnomaly = 1
AND pressureAnomaly.IsAnomaly = 1
THEN 'System Failure Likely'
WHEN (tempAnomaly.IsAnomaly = 1 AND humidityAnomaly.IsAnomaly = 1)
OR (tempAnomaly.IsAnomaly = 1 AND pressureAnomaly.IsAnomaly = 1)
THEN 'Multiple Anomalies Detected'
ELSE 'Single Anomaly'
END AS severity
INTO
[multi-metric-alerts]
FROM
MultiMetricAnomalies
WHERE
tempAnomaly.IsAnomaly = 1
OR humidityAnomaly.IsAnomaly = 1
OR pressureAnomaly.IsAnomaly = 1
= Related Resources¶
Core Topics¶
- Stream Processing Basics - Fundamental concepts
- Windowing Functions - Time-based analysis
- Edge Deployments - Deploy to IoT Edge
Integration Guides¶
Best Practices¶
- ML Model Tuning
- Alert Management
Last Updated: 2025-01-28 Complexity: Advanced Estimated Reading Time: 20 minutes